Corporate Headquarters 6855 Lyons Technology Circle + Suite 18 —— BUCK STEEL voll Froe "| CUSTOMER QUOTE Name Kenneth Benjamin Jr. Tel SePEeeE= Quote Date 05/18/2015 Company Jaredian Design Group Fax Valid Through 06/02/2015 Street TBD Email Sas Project ID BS15229 City TBD Sales Rep Brian Buck State ZZ Zip TBD Country US Virgin Islands Page tof 3 Project Building 1 Location Street TBD City TBD County TBD State ZZ Zip TBD Country US Virgin Islands Width Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Enclosed Occupancy Normal Length 61'-4" Wind Load 145MPH Snow Roof 0 Seismic S1 Column Straight Thermal Unheated Height 18'4"/20'4 Exposure C Snowls 1.0 Seismic Co Base Deluxe Formed Trim Snow Exp Sheltered 3/64" Roof Pitch .5:12 Live Load 20 SnowCt 1.0 Frame Single Slope Reducible Yes SnowCe 1.0 Collateral 0.5 Left Endwall Spacing 2 @ 20° Type Post and Beam Bracing Cable Girt Bypass Right Endwall Spacing 2 @ 20° Type Post and Beam Bracing Cable Girt Bypass Front Sidewall Spacing 3 @ 20° Type N/A Bracing Portal Girt Bypass Back Sidewall Spacing 3 @ 20° Type N/A Bracing Cable Girt Bypass Roof Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4" Color Not Specified Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4" Color Not Specified Engineering EXPORT BUILDING with final destination of Virgin Islands via PORT Everglades with unloading and freight forwarding by others. Export Notes package includes extra sheeting. nuts, bolts, fasteners, girts and purlins with all rollup doors specifically crated for export to provide additional protection. It is the customer's responsibility to VERIFY All CODES & LOADS used to design this building as being in accordance with local requirements. Total weight is estimated as XX,XXX Ibs. COD amount is to be paid in full 2 weeks prior to delivery to port. Building Pricing Qty Description 1 Base Building as per Engineering Specifications Included 1 Stamped Engineered Building Drawings (3 Sets) Included 1 Erecting Drawings (2 Sets) Included 1 Letter of Certification Included 1 Anchor Bolt Plans Included 1 All Frames Hot Dipped Galvanized, Secondary Members Pre-Galvanized Included 1 FSW 10 53/64" Below BSW Grade Included 1 FSW, BSW, REW Open to 5°-6" Included 1 Full Trim Package Including: Corner Trim, Eave Trim, Sculptured Rake Trim Included 1 Die-formed Ridge Cap Included 1 Closure Strip Package Included 1 Gutters & Downspouts Included 2 Framed Opening Standard 12° x 16° For Rollup Doors Included 1 Personnel Door 3070-M White Insulated Pre-Assembled Windlock Certified w/ Lever Handle w/ Threshold Included 2 Roll Up Steel Windlock Certified Non-Insulated w/ Chainhoist 12' x 16' Included 1 Roof Insulation 6"/ R19 WMP-VR w/ Starter Roll w/ Patch Tape Included 1 Wall Insulation 4" R13 WMP-VR w/ Starter Roll w/ Patch Tape Included 1 Building & Accessory Freight To Port Everglades Included 1 Export Package Including Extra Compnents and Special Crating Included Florida Georgia Tennessee Website Tel EFTA00602832

--=PAGE_BREAK=--

— BUCK STEEL Corporate Headquarters 6855 Lyons Technology Circle + Suite 18 Coconut Creek + FL + 33073 Toll Free Tel: Name Kenneth Benjamin Jr. Tel lz Quote Date 05/18/2015 Company Jaredian Design Group Fax Valid Through 06/02/2015 Street TBD Email FY Project ID BS15229 City TBD Sales Rep Brian Buck State ZZ Zip TBD Country US Virgin Islands Page 2o0f 3 Location Street TBD City TBD County TBD State ZZ Zip TBD Country US Virgin Islands Width 62" Code IBC 2009 SnowGnd 0 Seismic Ss Shell Enclosed Occupancy Normal Length 122° Wind Load 145MPH Snow Roof 0 Seismic $1 Column Tapered Thermal Unheated Height 12° Exposure C Snowls 1.0 Seismic Co Base Deluxe Formed Trim Snow Exp Sheltered Roof Pitch 1.5:12 Live Load 20 SnowCt 1.0 Frame Gable Symmetrical Reducible Yes SnowCe 1.0 Collateral 0.5 Left Endwall Spacing 25'/23°6"/21'6" Type Post and Beam Bracing Cable Girt Bypass Right Endwall Spacing 21'6"/23'6"/25' Type Post and Beam Bracing Cable Girt Bypass Front Sidewall Spacing 21'/4@20/21' Type N/A Bracing Cable Girt Bypass Back Sidewall Spacing 21/4@20/21' Type N/A Bracing Cable Girt Bypass Roof Panel Gauge 24 Style RROL Screw Type-Length Long Life-1 1/4" Color Not Specified Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4" Color Not Specified Engineering Notes Qty Description 1 Base Building as per Engineering Specifications Included 1 Stamped Engineered Building Drawings (3 Sets) Included 1 Erecting Drawings (2 Sets) Included 1 Letter of Certification Included 1 Anchor Bolt Plans Included 1 All Frames Hot-Dipped Galvanized, Secondary Members Pre-Galvanized Included 1 FSW 1'- 53/64" Below BSW Grade Included 1 LEW, BSW Open to 5'-6" For Block, REW Open to 2'-4" For Block Included 5 Misc Steel Columns To Support Roof From Below Floor(Max 30lb. per ft.. Bracing At Floor W/Hdware Included 1 Mod-2 Design 40', 20' Framelines #2-#6 Included 1 Full Trim Package Including: Corner Trim, Eave Trim, Sculptured Rake Trim Included 1 Die-formed Ridge Cap Included 1 Closure Strip Package Included 1 Gutters & Downspouts Included 2 Framed Opening Standard 18° x 10° Rolling Stee! Doors Included 1 Personnel Door 3070-M White Insulated Pre-Assembled Windlock Certified w/ Lever Handle w/ Threshold Included 2 Roll Up Windlock Certified Non-Insulated w/ Chainhoist 18° x 10° Included 1 Roof Insulation 6"/ R19 WMP-VR wi Starter Roll w/ Patch Tape Included 1 Wall Insulation 4"/ R13 WMP-VR wi Starter Roll w/ Patch Tape Included 1 Building & Accessory Freight To Port Everglades Included 1 Export Package Including Extra Compnents and Special Crating Included Total Building Website EFTA00602833

--=PAGE_BREAK=--

Corporate Headquarters 6855 Lyons Technology Circle + Suite 18 a BUCK STEEL Toll Free Tel Coconut Creek + FL + 33073 Name —_ Kenneth Benjamin Jr. Tt Quote Date 05/18/2015 Company Jaredian Design Group Fax Valid Through 06/02/2015 Street TBD Email | sd Project ID BS15229 City TBD Sales Rep Brian Buck State ZZ Zip TBD Country US Virgin Islands Page 3of 3 Project Building Pricing Qty Description 1 Base Building as per Engineering Specifications 126,640.00 Project Option Pricing (Options are NOT INCLUDED in the building price above) Qty Description Unit Extended 1 Stamped Engineered Foundation Drawings (3 Sets) 5,250.00 5,250.00 1 Project Erecting Including Equipment Rental, Unloading, and Labor(ESTIMATE) 36,000.00 36,000.00 IMPORTANT NOTES - PLEASE READ * This quote is based on Buck Steel's interpretation of plans and/or conversations with the customer, Buck Steel is NOT responsible for any errors and/or ommissions. * Carefully check this quote for completeness and verify the accuracy of the information contained within. * This quote is valid through 6/2/2015, and is subject to review of pricing. Revisions to quote may result in a price adjustments. ¢ Erecting is NOT included in this quote, unless specifically listed. « Anchor bolts are NOT included in this quote and are NOT provided by Buck Steel. « Concrete is NOT included in this quote and is NOT provided by Buck Steel « Buck Steel and/or the Building Engineer is NOT the "Engineer of Record”. The customer/owner is responsible for any "special building inspector" or "structural engineer" required by the city or county for pre and post construction inspections. « All prices are in USD. ¢ Pricing contained in this quote does not include any applicable sales taxes. EFTA00602834