Madison Belvedere 10 East 29th Street mo New York City LEED Sustainable Re-Design = EFTA00282013

--=PAGE_BREAK=--

One Bedroom Apartment 670 square feet 2 residents LIVING ROOM/DINING ROOM EFTA00282014

--=PAGE_BREAK=--

LEED CREDITS FOR APPLICATION * Water Efficiency: Pre-requisite 1 Water Use Reduction * Energy & Atmosphere: Credit 1.2 Optimize Energy Performance - Lighting Controls * Energy & Atmosphere: Credit 1.4 Optimize Energy Performance - Equipment & Appliances * Materials & Resources: Prerequisite 1 Storage and Collection of Recyclables * Indoor Environmental Quality: Credit 4.2 Low-emitting Materials - Paints and Coatings EFTA00282015

--=PAGE_BREAK=--

Water Efficiency: Pre-requisite 1 Water Use Reduction Intent: To further increase water efficiency within the tenant space to reduce the burden on the municipal water supply and wastewater systems. Requirements: Reduce water usage from baseline by 20% through water closets, urinals, lavatory faucets, showers, kitchen sink faucets, and pre-rinse spray valves. Kohler-WaterSense Moen’s Caldwell Classic Moen’s Envi Chrome Toilet brushed nickel two-handle infinite 8" diameter eco- low arc bathroom faucet performance showerhead Cimarron® Comfort Height® 1.28 gpf toilet with look for Class Six® technology 1.5GPM 2.0 GPM EFTA00282016

--=PAGE_BREAK=--

LEED-Cl 20 Letter Template ‘WE Credit 1: Water Use Reduction ‘esign Total uses by all occupants Total Dalty Volume [gal] NG ww PN) om Wastewater Generation Reduction: 28.35% = xo) ® a O Cc O —_ O =) xe) ) ~ ® ep) — _. cd) —_ = | ma ma pe ma ma ma me ma | ms Ze ma ms | 2° | ma pe | e | a - r ET pees a i EE: een iciency Water Eff

--=PAGE_BREAK=--

Energy & Atmosphere: Credit 1.2 Optimize Energy Performance - Lighting Controls Intent: To achieve increasing levels of energy conservation beyond the prerequisite standard to reduce environmental and economic impacts associated with excessive energy use: Requirements: 1) Install daylight responsive controls in all regularly occupied daylit spaces within 15 feet of windows and under skylights. Daylight controls must switch or dim electric lights in response to the presence or absence of daylight illumination in the space. 2) Install occupancy sensors for 75% of the connected lighting load. \ Q Q , aon SY Lutron: Radio Powr Savr Lutron: Radio Powr Savr Wireless Daylight Sensor Wireless Occupancy Sensor EFTA00282018

--=PAGE_BREAK=--

Energy & Atmosphere: Credit 1.2 Optimize Energy Performance - Lighting Controls li. Aun Ge a EFTA00282019

--=PAGE_BREAK=--

Energy & Atmosphere: Credit 1.4 Optimize Energy Performance - Equipment & Appliances Intent: To achieve increasing levels of energy conservation beyond the prerequisite standard to reduce environmental and economic impacts associated with excessive energy use. Requirements: Instal appliances of which 70% are ENERGY STAR qualified. BOSCH - 24" Tall Tub Whirlpool - 25.1 Cu. Ft. Built-In Dishwasher Side-by-Side Refrigerator with Thru-the-Door ENERGY STAR Qualified Ice and Water 300 kWh/year ENERGY STAR Qualified 577 kWh/year Samsung LCD HDTV Television ENERGY STAR Qualified 167 kWh/year Dell Inspiron 1440 Notebook Computer ENERGY STAR Qualified 29.2 kWh/year ENERGY STAR EFTA00282020

--=PAGE_BREAK=--

Energy & Atmosphere: Credit 1.4 Optimize Energy Performance - Equipment & Appliances LEED-Cl 2.0 Letter Template EA Credit 1.4: Optimize Energy Performance, Equipment Percentage of ENERGY STAR Rated Power for Equipment and Applicances in Project * Rated power measured in kWh/year

--=PAGE_BREAK=--

Materials & Resources: Prequisite 1 Storage and Collection of Recylables Intent: To facilitate the reduction of waste generated by building occupants that is hauled to and disposed of in landfills. Requirements: Provide an easily accessible dedicated area or areas for the collection and storage of materials for recycling for the tenant space. Materials must include at a minimum paper, corrugated cardboard, glass, plastics, and metals. The Container Store 2 Bin Recycling Storage Step on the pedal and the lid on the top bin opens The lower bin features a convenient handle so you can pull it open Image of 12" x 10-3/4" x 32-1/2"h 4 product in kitchen EFTA00282022

--=PAGE_BREAK=--

Indoor Environmental Quality: Credit 4.2 Low-emitting Materials - Paints and Coatings Intent: To reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants. Requirements: Paints and coatings used on the interior of the building must comply with the following criteria as applicable to the project scope: *Paints and coatings applied to *Anti-corrosive and anti-rust paints *Clear wood finishes, floor coatings, interior wallsand ceilings must applied to interior ferrous metal s stains, primers,and shellacs applied to not exceed the VOC content limits ubstrates must not exceed the VOC interior elements: must not exceed the content limit of 250 g/L (GS-03). VOC content limits established in established by GS-11. South Coast EFTA00282023

--=PAGE_BREAK=--

Indoor Environmental Quality: Credit 4.2 Low-emitting Materials - Paints and Coatings Aura Paint by Benjamin Moore ; GS 11 Natura Primer by Benjamin Moore 0 50 — | GS-11 — primer BioShield Natural Floor Finish 100 g/L or less 100 g/L | SCAQMD #1113 clear wood finish 7 1GSH IELO BiolShield Natural Resin Wood Floor Finish Aura Interior Paint by Benjamin Moore Natura Interior Primer 100g?L or less VOC 48 g/L VOC Zero VOC EFTA00282024

--=PAGE_BREAK=--

fore es 2 ee } ceeeeaceneeccenceerneneteartt ft be MC ceececen! (CCE CCU ECE EFTA00282025